The EL8020 Series provides media conversion between 10/100/1000BASE-TX and 100/1000 SFP Fiber. Built specifically for mission critical applications in harsh environments, the EL8020's hardened design features high shock & vibration resistance, electrical noise immunity, wide operating temperature range from -40 to 75ฐC (-40 to 167ฐF), and aluminum housing. With two power inputs, link down alarming, Link-Fault-Pass-Through and a wide range of fiber connectivity options, the EL8020 is the ideal media converter for environments where connectivity is crucial.


Technology
- Standards
- IEEE 802.3 10BASE-T
- IEEE 802.3u 100BASE-TX
- IEEE 802.3ab 1000BASE-T
-
- Forward and Filtering Rate
- 14,880pps for 10Mbps
- 148,810pps for 1000Mbps
- 1,488,100pps for 1000Mbps
-
- Processing Type
- Auto Negotiation
- Auto MDI/MDIX
Power
- Power Consumption
- 0.912W Max, 76mA@12VDC, 38mA@24VDC, 19mA@48VDC
-
- Protection
- Overload Current Protection
- Reverse Polarity Protection
Mechanical
- Casing
- Aluminum Case
- IP30
-
- Dimensions
- 35.8 x 90 x 100mm (W x D x H)
(1.41" x 3.54" x 3.94")
-
- Weight
- 0.23Kg (0.51lbs.)
-
Interface
- Ethernet Port
- 10/100/1000BASE-TX: 1 port
- 100/1000 SFP: 1 port
-
- LED Indicators
- Per Unit: Power 1, Power 2, Fault, LFPT
- Per Port: Link/Activity
-
- DIP Switch
- No.1: LFPT On/Off
- No.2: Alarm for copper port On/Off
- No.3: Alarm for fiber port On/Off
- No.4: Auto-negotiation for fiber port On/Off
-
- Alarm Contact
- Relay contact rating with current 0.6A/30VDC
Environment
- Operating Temperature
- -40 to 75ฐC (-40 to 167ฐF)
-
- Storage Temperature
- -40 to 85ฐC (-40 to 185ฐF)
-
- Ambient Relative Humidity
- 5% to 95% (non-condensing)
Regulatory Approvals
- ISO
- Manufactured in an ISO 9001 facility
-
- Industrial Compliance
- EN 50121-4
-
- EMI
- FCC Part 15B Class A
- VCCI Class A
- EN 55032
- EN 61000-3-2
- EN 61000-3-3
- EN 61000-6-3
-
- EMS
- EN 61000-6-2
- EN 61000-4-2 (ESD Standards)
- EN 61000-4-3 (Radiated RFI Standards)
- EN 61000-4-4 (Burst Standards)
- EN 61000-4-5 (Surge Standards)
- EN 61000-4-6 (Induced RFI Standards)
- EN 61000-4-8 (Magnetic Field Standards)
-
- Environmental Test Compliance
- IEC 60068-2-6 Fc (Vibration Resistance)
- IEC 60068-2-27 Ea (Shock)
- FED STD 101C Method 5007.1 (Free fall w/package)
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Features
- Link Fault Pass Through (LFPT)
- Power failure alarm
- Dual-rate at Copper and Fiber Connection
|
|
 |
 |
 |
 |

|