Home > Perle > Perle Accessories > Perle Industrial DIN Rail Power Supplies >

28668028

Perle 28668028
See any errors on this page?
Please let us know.
 
Perle QUINT-PS/3AC/24DC/40 Power Supply - QUINT power supply for DIN rail mounting with SFB (Selective Fuse Breaking) Technology, input: 3-phase, output: 24 V DC/40 A
MSRP: $1,238.00
ESP Price: $1,114.80
Contact us for Partner Pricing. (more info)



Availability: Usually Ships in 24 Hours; However, Due To Shortages Contact Sales to Verify
Product Code: 28668028

Description Technical Specs Drivers & Downloads
 

QUINT 3-Phase Power Supplies offer a range of rugged AC to DC and DC to DC Converters built to meet the high stability and efficiency expectations of industrial, machine automation and process control environments. They also feature the unique combination of preventive function monitoring and power reserve in an incredibly compact size. Perfect for use in high power applications, these Switching (switch mode) Power Supplies ensure a regulated output voltage even in the event of voltage fluctuations in the power supply network. During parallel operation, and when connected to different phases, loads are reliably supplied even in the event of problems with the input voltage. With all required safety certifications to support ITE (Information Technology Equipment), ruggedized packaging, extended operating temperatures, high peak load capabilities and high isolation voltages, QUINT Industrial Power Supplies are designed to meet the needs of your industrial application.

POWER BOOST: reliably start difficult loads

Power Boots Diagram

A high degree of flexibility is required to configure, optimize and expand large systems. To optimally adapt a system or machine to your requirements, a power reserve in the power supply unit is crucial. The QUINT supplies up to 50% additional current without a voltage drop. This is useful when it is not possible to predict which loads will be switched on at the same time or high switch-on currents of capacitive loads have to be absorbed without voltage dips. With the QUINT Power Boost function a static boost will continuously provide up to 125% of the nominal current. In addition, you can use the dynamic boost to supply up to 200% of the nominal current for 5 seconds when starting up heavy loads.

Preventive function monitoring reports critical operating states before they occur

Power Boots Diagram

With a QUINT Industrial Power Supply, the output voltage and output current are constantly monitored. Preventive function monitoring visualizes critical operating states and indicates them locally and remotely to the controller as follows:

  • Via LED
  • Via floating relay contact
  • Via active switching output

Industrial operating temperature of -25°C to +70°C

Equipment found in traffic management, oil and gas pipelines, weather tracking, industrial and outdoor applications must function in temperatures that cannot be supported by a commercial power supplies. With an operating temperature of -25°C to +70°C, and reliable device start-up at -40°C, the QUINT Industrial Power Supply is ideal for use with equipment subjected to harsh environments and severe temperatures.

High efficiency and low no load power consumption

Compared with other products on the market, the QUINT Industrial Power Supply provides excellent energy savings. With a very low no load power consumption and high efficiency at nominal load, just a small amount of electrical energy is converted into undesired heat energy making these very ECO friendly power supplies.

QUINT Industrial Power Supply Diagram

SFB (Selective Fuse Breaking) Technology

SFB Technology can be used to quickly and reliably trip miniature circuit breakers and fuses connected on the secondary side. In the event of a short circuit on the secondary side, the QUINT supplies up to 6 times the nominal current for 15 ms. Faulty current paths are switched off selectively, the fault is located, and important system parts remain in operation. Loads that are connected in parallel are still supplied with energy ensuring continued operation of these system parts.

  • Tripping circuit breakers: The circuit breaker is typically tripped by the high SFB current within 3 to 5 ms. As a result, any voltage dips for loads connected in parallel are avoided.
  • Tripping a fuse: Fuses are tripped by melting the predetermined breaking point inside the fuse capsule. The tripping characteristic of the fuse is described by the melting integral (I²t). A high current is crucial in order to achieve a very short tripping time.
NFC Image

Near Field Communication (NFC)

Near Field Communication (NFC) is a transmission standard for wireless and contactless data exchange at a close distance. With NFC, you can easily parameterize QUINT Power Supply settings such as define signaling thresholds for preventive function monitoring, adjust output voltage, and adapt the output characteristic curve to your specific requirements using a PC, mobile phone, or mobile terminal device. You can also save and send configuration profiles on your mobile terminal device. QUINT Power NFC App on the Google Play Store.

Ideal application environments for a QUINT 3-Phase Power Supply

  • Drive motors and other devices
  • Machine building
  • Automated production process
  • Industrial control, automation, assembly, and test equipment
  • Building control, security and surveillance, and climate control systems.
  • Power countless industrial automation devices such as sensors, controllers and valves

Other reasons to choose a QUINT 3-Phase Power Supply

  • Robust input side: high noise immunity, integrated gas-filled surge arrester (up to 6 kV), and ≥ 20 ms mains failure buffer time
  • Narrow, slim-line design saves space in the control box
  • Voltage Isolation input/output: 4 kV AC
  • Protections: Short-circuit, Overload, Over voltage, Over-temperature
  • High MTBF (Mean Time Between Failure) values
Features
  • Output Voltages: 24 or 48 V DC
  • Adjustable Output Voltage Ranges: 18 to 56 V DC
  • Output Amps: 10, 20 or 40 Amps
  • Output Watts: 240, 480 or 960 W
  • Will operate with 3-phase or 2-phase AC or DC input Voltage Ranges


Browse for more products in the same category as this item: